Schematics are drawn on a 4 mm grid. Hold Alt while moving or drawing for a 1 mm step. The arrow keys move the selection one grid step.

Symbols

The Symbols tab holds the IEC 60617 library, grouped (contacts, coils, protection, machines, sensors, terminals, PLC, interruptions and potentials…), with a search field. Click a symbol and click on the page to place it; each click places another copy with the next free tag (-K1, -K2…). Esc stops.

The library has three sections, Electrical, P&ID (see P&ID) and Fluid power (see Fluid power). Click a section or group heading to fold it; the number beside it tells how many symbols it holds. Collapse all and Expand all fold or open everything, A–Z sorts the symbols of each group by name. Only the section of the page's type is open (electrical on a schematic, P&ID on a P&ID page, fluid power on a fluid power page) until you open another. Recently used on top keeps the last twelve symbols you chose. While you search, every group with a match is open.

Wires

The Wire tool (W) draws a wire from a connection point: click the start, click the corners, click the end on another connection point or wire. Double-click ends it at a free point. Backspace takes back the last corner, Esc cancels.

Jumpers (T-node)

Jumper (Insert menu and toolbar) draws like the wire tool: draw from a wire to a connection point (or the other way), and the branch point becomes a jumper T-node, drawn without its dot. Its branch is a jumper, not a wire, and goes to the nearer end of the line (Branch to in the junction properties). Click a branch point with the tool to make it a jumper or a plain junction again; the junction properties have a Jumper box too.

A jumper is made with a jumper part, not cut from wire: it has no length, no route on the panel layout and no wire markers, and it is not in the wire list. The Connections table shows it as Jumper; between two terminals it is in the Jumpers column of the terminal table. Jumpers between neighbouring terminals of a strip are made as before with Add jumper on the selected terminals.

Automatic connections

Two connection points that face each other on one line, with nothing between them, are connected without a wire: place a contact right below another and they join. The line is drawn for you and follows when you move the symbols. A point with a drawn wire does not take automatic connections.

To keep two facing points apart, use Insert → Connection break and click the automatic connection.

Click an automatic connection to select it. Its properties show where it goes from and to, its number, colour and cross-section. Changing the colour, the cross-section or an end (to another free point of the symbol), or Draw as wire, makes it a drawn wire between the same points; the page looks the same. It cannot be deleted: move a symbol, or put a connection break on it.

Potentials and interruption points

Place them with Potential point and Interruption point (Insert menu and toolbar): give the name once (the last one is offered, the project's names are in the list), then click to place points of that name one after another; R turns, Esc ends. A new potential point takes the wire colour and cross-section of the points of its name.

Location box

Location box (B) draws a rectangle that gives a function and location to the symbols inside it, e.g. a field device +FIELD on a cabinet page. Its codes are shown once in its corner; tags inside it are shown without them.

Text and graphics

Text (T), Line (L), Rectangle and Circle are on the toolbar and in the Insert menu. Texts have a size and turn with R; lines have a weight and can be dashed. Graphics have no electrical meaning.

Wire numbers

How wires are marked is set in Project properties… → Wire numbering:

ModeExampleUpdated
Source/target, one name per wire-K1:A1/-X1:3live
Source/target, at each end-X1:3 at the -K1:A1 endlive
By place: page.column.n3.4.1Number wires
Sequential1, 2, 3Number wires

New projects name each wire by its two ends, -K1:A1/-X1:3, written once along the middle of the wire: right of an upright wire, above a level one, made smaller on a short wire and broken after the / when it is still too long. A wire to an interruption point is named after the device on the other side of the point, as in the wire list.

The numbered modes give one number to each net. Number wires numbers new nets and keeps the others; Renumber all wires numbers them all again. A number typed by hand in the Number column of the Connections table is kept.